Lighting · Cables

Lighting cables: fixture to controller

Lighting cables

They connect the fixture to the controller: SMR-03V-B on the light side, lengths from 1 to 30 m, one-to-one versions and one-to-two splitters for paired lighting.

Price on requestAn engineer will confirm pricing and lead time in the first reply.
Lead time
from 5 days
Warranty
36 months
Find the right model
Hikrobot Lighting cables: fixture to controller

Part numbers and versions

Insulation resistance≥10 MΩ1,2

Other colours

Part numberPNIntegral cable lengthCable typeInput channelsJacket materialCable diameter
MV-LW-002-1-S(C)
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365001167
2 m
light cable1
—
—
—
MV-LW-003-1-S(C)
All specifications
Connector A
SMR-03V-BC1
Connector B
SMR-03V-B1
Cable construction
—
Minimum bending radius
60 mm (min.)1
Bending endurance
5000000 (max.) @ ±90° bending1
Connector mating durability
200001
Ingress protection
IP301
Working temperature
-20…40 °C1
Storage temperature
-20…60 °C1
Humidity
20…85 % @ non-condensing1
Certification
RoHS1
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365001399
3 m1
Lighting Cables1
11
TPU1
5 mm1
MV-LW-003-2-S
All specifications
Connector A
SMR-03V-BC
Connector B
SMR-03V-B
Cable construction
—
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101330
3 m
Lighting Cables
2
TPU
5 mm
MV-LW-005-1-24M6J(C)
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101328
5 m
light cable1
—
—
—
MV-LW-005-1-B
All specifications
Connector A
12M-2B
Connector B
12M-2A
Cable construction
—
Minimum bending radius
66 mm (min.)
Bending endurance
1000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
not available
Dielectric withstand voltage
—
Insulation resistance per length
—
310100505
5 m
Lighting Cables
1
PVC
5.5 mm
MV-LW-005-1-B19
All specifications
Connector A
19M-2K
Connector B
19M-2A
Cable construction
—
Minimum bending radius
52.5 mm (min.)
Bending endurance
2000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101110
5 m
Lighting Cables
1
PVC
7.5 mm
MV-LW-005-1-B19(C)
All specifications
Connector A
19M-2K1
Connector B
19M-2A1
Cable construction
—
Minimum bending radius
52.5 mm (min.)1
Bending endurance
2000000 (max.)1
Connector mating durability
200001
Ingress protection
IP30 @ when properly installed1
Working temperature
-20…40 °C1
Storage temperature
-20…60 °C1
Humidity
20…85 % @ non-condensing1
Certification
RoHS1
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365001857
5 m
light cable1
11
PVC1
7.5 mm1
MV-LW-005-1-G
All specifications
Connector A
19M-6G
Connector B
19M-6H
Cable construction
—
Minimum bending radius
114 mm (min.)
Bending endurance
1000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310100648
5 m
Lighting Cables
1
PVC
9.5 mm
MV-LW-005-1-G(C)
All specifications
Connector A
19M-6G1
Connector B
19M-6H1
Cable construction
—
Minimum bending radius
114 mm (min.)1
Bending endurance
1000000 (max.)1
Connector mating durability
200001
Ingress protection
IP30 @ when properly installed1
Working temperature
-20…40 °C1
Storage temperature
-20…60 °C1
Humidity
20…85 % @ non-condensing1
Certification
RoHS1
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101329
5 m
light cable1
11
PVC1
9.5 mm1
MV-LW-005-1-K
All specifications
Connector A
20M-4K
Connector B
20M-4J
Cable construction
—
Minimum bending radius
87.6 mm (min.)
Bending endurance
1000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310100469
5 m
Lighting Cables
1
PVC
7.3 mm
MV-LW-005-1-S(C)
All specifications
Connector A
SMR-03V-BC1
Connector B
SMR-03V-B1
Cable construction
—
Minimum bending radius
48 mm (min.)1
Bending endurance
5000000 (max.) @ ±90° bending1
Connector mating durability
200001
Ingress protection
IP301
Working temperature
-20…40 °C1
Storage temperature
-20…60 °C1
Humidity
20…85 % @ non-condensing1
Certification
RoHS1
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365001398
5 m1
Lighting Cables1
11
TPU1
4 mm1
MV-LW-005-1-S-LZ(C)
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365007043
5 m
light cable1
—
—
—
MV-LW-005-1-S7B
All specifications
Connector A
SA1610/P7B
Connector B
SA1610/P7B
Cable construction
—
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101145
5 m
Lighting Cables
1
PVC
7.5 mm
MV-LW-005-2-S
All specifications
Connector A
SMR-03V-BC
Connector B
SMR-03V-B
Cable construction
—
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365003832
5 m
Lighting Cables
2
TPU
5 mm
MV-LW-010-1-B
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365003319
10 m
light cable1
—
—
—
MV-LW-010-1-B(C)
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365003719
10 m
light cable1
—
—
—
MV-LW-010-1-G
All specifications
Connector A
19M-6H
Connector B
19M-6G
Cable construction
—
Minimum bending radius
66.5 mm (min.)
Bending endurance
2000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310100974
10 m
Lighting Cables
1
PVC
9.5 mm
MV-LW-010-1-S(C)
All specifications
Connector A
SMR-03V-BC1
Connector B
SMR-03V-B1
Cable construction
—
Minimum bending radius
48 mm (min.)1
Bending endurance
5000000 (max.) @ ±90° bending1
Connector mating durability
200001
Ingress protection
IP301
Working temperature
-20…40 °C1
Storage temperature
-20…60 °C1
Humidity
20…85 % @ non-condensing1
Certification
RoHS1
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365001746
10 m1
Lighting Cables1
11
TPU1
4 mm1
MV-LW-010-2-S
All specifications
Connector A
SMR-03V-BC
Connector B
SMR-03V-B
Cable construction
—
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310100828
10 m
Lighting Cables
2
TPU
5 mm
MV-LW-015-1-B19
All specifications
Connector A
19M-2A
Connector B
19M-2B
Cable construction
—
Minimum bending radius
56.75 mm (min.)
Bending endurance
10000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101111
15 m
Lighting Cables
1
TPU
7.5 mm
MV-LW-015-1-G
All specifications
Connector A
19M-6G
Connector B
19M-6H
Cable construction
—
Minimum bending radius
106.8 mm (min.)
Bending endurance
5000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310100470
15 m
Lighting Cables
1
PVC
8.9 mm
MV-LW-015-1-K
All specifications
Connector A
20M-4J
Connector B
20M-4K
Cable construction
—
Minimum bending radius
54.75 mm (min.)
Bending endurance
10000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101311
15 m
Lighting Cables
1
TPU
7.3 mm
MV-LW-015-1-S(C)
All specifications
Connector A
SMR-03V-BC1
Connector B
SMR-03V-B1
Cable construction
—
Minimum bending radius
48 mm (min.)1
Bending endurance
5000000 (max.) @ ±90° bending1
Connector mating durability
200001
Ingress protection
IP301
Working temperature
-20…40 °C1
Storage temperature
-20…60 °C1
Humidity
20…85 % @ non-condensing1
Certification
RoHS1
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365003121
15 m1
Lighting Cables1
11
PVC1
4 mm1
MV-LW-015-1-S-LZ(C)
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365001906
15 m
light cable1
—
—
—
MV-LW-020-1-B
All specifications
Connector A
12M-2K
Connector B
12M-2A
Cable construction
—
Minimum bending radius
38.5 mm (min.)
Bending endurance
2000000 (max.) @ ±90° bending
Connector mating durability
20000
Ingress protection
IP30
Working temperature
-20…40 °C
Storage temperature
-20…60 °C
Humidity
20…85 % @ non-condensing
Certification
RoHS
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
310101112
20 m
Lighting Cables
1
PVC
5.5 mm
MV-LW-030-1-B
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365003020
30 m
light cable1
—
—
—
MV-LW-030-1-S(C)
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
365003660
30 m
light cable1
—
—
—
MV-LW-H-001-1-19M8A
All specifications
Connector A
19M-8A
Connector B
19M-8A
Cable construction
—
Minimum bending radius
105 mm
Bending endurance
2000000 @ ±90° bending
Connector mating durability
500 (max.)
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 %
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
300 V
Insulation resistance per length
≥10 MΩ/km
101517857
1 m
Light source extension cable
1
PVC
8.75 mm
MV-LW-H-001-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
3 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102083
1 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-003-1-12M5A
All specifications
Connector A
—
Connector B
—
Cable construction
—
Minimum bending radius
—
Bending endurance
—
Connector mating durability
—
Ingress protection
—
Working temperature
—
Storage temperature
—
Humidity
—
Certification
—
Flame resistance rating
—
Dielectric withstand voltage
—
Insulation resistance per length
—
101524421
3 m
light cable1
—
—
—
MV-LW-H-003-1-19M8A
All specifications
Connector A
19M-8A
Connector B
19M-8A
Cable construction
—
Minimum bending radius
105 mm
Bending endurance
2000000 @ ±90° bending
Connector mating durability
500 (max.)
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 %
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
300 V
Insulation resistance per length
≥10 MΩ/km
101517858
3 m
Light source extension cable
1
PVC
8.75 mm
MV-LW-H-003-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
3 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102084
3 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-005-1-19M8A
All specifications
Connector A
19M-8A
Connector B
19M-8A
Cable construction
—
Minimum bending radius
105 mm
Bending endurance
2000000 @ ±90° bending
Connector mating durability
500 (max.)
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 %
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
300 V
Insulation resistance per length
≥10 MΩ/km
101517859
5 m
Light source extension cable
1
PVC
8.75 mm
MV-LW-H-005-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
3 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102085
5 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-007-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
3 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102086
7 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-010-1-19M8A
All specifications
Connector A
19M-8A
Connector B
19M-8A
Cable construction
—
Minimum bending radius
105 mm
Bending endurance
2000000 @ ±90° bending
Connector mating durability
500 (max.)
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 %
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
300 V
Insulation resistance per length
≥10 MΩ/km
101517861
10 m
Light source extension cable
1
PVC
8.75 mm
MV-LW-H-010-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
2 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102087
10 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-015-1-19M8A
All specifications
Connector A
19M-8A
Connector B
19M-8A
Cable construction
—
Minimum bending radius
105 mm
Bending endurance
2000000 @ ±90° bending
Connector mating durability
500 (max.)
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 %
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
300 V
Insulation resistance per length
≥10 MΩ/km
101517863
15 m
Light source extension cable
1
PVC
8.75 mm
MV-LW-H-015-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
2 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102088
15 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-020-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
2 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102089
20 m
Light Source Extension Cable(s)
1
PVC
5 mm
MV-LW-H-030-1-19M8A
All specifications
Connector A
19M-8A
Connector B
19M-8A
Cable construction
—
Minimum bending radius
105 mm
Bending endurance
2000000 @ ±90° bending
Connector mating durability
500 (max.)
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 %
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
300 V
Insulation resistance per length
≥10 MΩ/km
101517864
30 m
Light source extension cable
1
PVC
8.75 mm
MV-LW-H-030-1-S
All specifications
Connector A
SMR-03V-B
Connector B
SMR-03V-BC
Cable construction
2 cores 24 AWG
Minimum bending radius
60 mm (min.)
Bending endurance
5000000 (max.) @ U-type bending
Connector mating durability
2000
Ingress protection
IP55 @ when properly installed
Working temperature
0…80 °C
Storage temperature
-20…80 °C
Humidity
20…90 % @ non-condensing
Certification
RoHS2.0
Flame resistance rating
VW-1
Dielectric withstand voltage
30 V
Insulation resistance per length
≥20 MΩ/km
310102090
30 m
Light Source Extension Cable(s)
1
PVC
5 mm

1 unofficial data
2 not stated for all variants

FAQ

What connection is specified at the lighting-fixture end?

The light side is identified as SMR-03V-B. The opposite end varies across S, B, B19, G, K, S-LZ, S7B, 12M5A, 19M8A, and 24M6J versions, so both ends must be matched.

What installed distances can be covered by the listed lengths?

The range provides 1 m, 2 m, 3 m, 5 m, 7 m, 10 m, 15 m, 20 m, and 30 m choices. Availability depends on the connector suffix, so the required ending and distance need to be checked together.

How are paired lights connected within this cable family?

One-to-two splitter versions are provided for paired lighting, while one-to-one cables serve a direct fixture-to-controller path. Splitter entries occur at 3 m, 5 m, and 10 m in the listed MV-LW group.

Do equal cable lengths imply the same controller-side ending?

No. At 5 m, for example, the table includes multiple B, B19, G, K, S, S-LZ, S7B, 19M8A, and 24M6J designations. Length does not replace the connector-suffix check.

How do MV-LW and MV-LW-H designations divide the choices?

MV-LW contains direct and splitter variants with several controller-side suffixes. MV-LW-H runs from 1 m to 30 m and lists S, 12M5A, and 19M8A endings at selected distances.

Typical applications