Hikrobot MV-CH100-60GM

4096×2460 pxCMOS, stacked BSI11.6 fpsGigEIP40
Price on requestAn engineer will confirm pricing and lead time in the first reply.
Lead time
from 5 days
Warranty
36 months
Find the right model
Hikrobot MV-CH100-60GM

Tasks and place in the range

High-detail mono acquisition is the defining role of MV-CH100-60GM: 4096 × 2460 at 11.6 fps. The CMOS sensor uses a global shutter; its 3.45 × 3.45 µm pixels cover a 1 in sensor; the image path is Gigabit Ethernet; the optical interface is C-mount. The monochrome output suits measurements and contrast-based inspection where color separation is not the measured feature.

The stated imaging characteristics support distributed dimensional inspection, wide-object measurement and edge localization. The global shutter keeps the 4096 × 2460 frame temporally aligned on moving or indexed objects, while 11.6 fps sets the available acquisition cadence. PoE can carry power with the Ethernet link, or the camera can use a 9 V DC to 24 V DC input.

Range placement becomes clear beside MV-CH100-60UM and MV-CH120-10GM. MV-CH100-60UM changes the frame path to USB 3.0 and records mono with 36 fps. Prefer it when USB 3.0 is the required image interface. MV-CH120-10GM provides 4096 × 3000 mono capture with 9.9 fps through Gigabit Ethernet. Prefer it when 9.9 fps acquisition matches the line cadence.

Specifications

Shutterglobal
Nominal optical sensor format1″
Sensor resolution4096×2460 px
Maximum frame rate11.6 fps @ Mono8, resolution 4096×2460 px
Color modemono
Lens mountC-mount
Data interfaceGigE (Fast Ethernet compatible)
Sensor technologyCMOS, stacked BSI
Pixel size3.45×3.45 µm
Dynamic range58.2 dB
Signal-to-noise ratio43 dB
Exposure time80…10000000 µs
Auto exposureOff, Once, Continuous
Gain0…24 dB
Pixel formatMono8, Mono10, Mono10Packed, Mono12, Mono12Packed
Binning1x1, 2x2, 4x4
Decimation1x1, 2x2, 4x4
Protocol compatibilityGigE Vision, GenICam
Communication protocol versionsGigE Vision 2.0
Third party software protocolGigE Vision
Client softwareMVS
Operating systemsWindows 7 (32/64-bit), Windows 10 (32/64-bit), Windows 11 (64-bit), Linux (32/64-bit)
Digital I/O lines1 input, opto-isolated, line 0; 1 output, opto-isolated, line 1; 1 bidirectional line, non-isolated, line 2
Digital I/O connectorP7 6-pin
Power supply9…24 V
Power deliveryexternal power supply, PoE
PoE supportyes
Power consumption2.9 W (typical) @ DC, supply voltage 12 V
Ingress protectionIP40 @ with lens and cables properly installed
Working temperature-10…50 °C
Storage temperature-30…70 °C
Humidity20…95 % @ non-condensing
Dimensions29×44×59 mm
Weight92 g (approx.)
CertificationCE, RoHS, KC
Reverse imagehorizontal, vertical

Documents

Datasheet MV-CH100-60GMGC · PDF · 0.5 MB · English · revised 26 Sept 2025

Selection and applications

Mono inspection at 4096 × 2460. Geometric capture of moving or indexed parts. Acquisition at 11.6 fps over Gigabit Ethernet.

Minimum kit: Start with MV-CH100-60GM, a lens with the C-mount interface covering the 1 in sensor, a cable for Gigabit Ethernet, and PoE or a 9 V DC to 24 V DC supply.

Nearby in the range: MV-CH100-60UM — Prefer it when USB 3.0 is the required image interface; MV-CH120-10GM — Prefer it when 9.9 fps acquisition matches the line cadence.

Cables and accessories for this model

Compatibility per manufacturer data.

Data cables
GigE
Power
Power

All accessory families →

FAQ

How do shutter timing and frame rate shape MV-CH100-60GM motion capture?

MV-CH100-60GM uses a global shutter that exposes the 4096 × 2460 frame on one timing basis, supporting geometric capture of moving and indexed parts. It reaches 11.6 fps.

What link and power arrangement are required for MV-CH100-60GM?

MV-CH100-60GM transfers images through Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s). PoE can carry power with the Ethernet link, or the camera can use a 9 V DC to 24 V DC input. Power consumption is 2.9 W.

How should optics be selected for the MV-CH100-60GM sensor and mount?

The optical chain for MV-CH100-60GM is anchored by the C-mount interface. Its stated sensor format is 1 in, which sets the minimum image-circle coverage. The 3.45 × 3.45 µm pixels also set the lens-resolution target for a 4096 × 2460 frame. After coverage and resolving power are checked, choose focal length from the required scene geometry.

Which housing and operating limits apply to MV-CH100-60GM?

MV-CH100-60GM has an IP40 enclosure and a 29 × 44 × 59 mm body. The working range is -10 to 50 °C. The humidity range is 20 to 95 % RH. Listed camera mass is 92 g; include it in the bracket and motion-load calculation.

How do MV-CH100-60GM and MV-CH100-60UM differ as selection options?

MV-CH100-60GM records mono images with 11.6 fps through Gigabit Ethernet; its lens connection is C-mount. MV-CH100-60UM records mono images with 36 fps through USB 3.0 and uses C-mount optics. Prefer it when USB 3.0 is the required image interface.

Which acquisition and image-stream details are stated for MV-CH100-60GM?

The documented image path is Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s), delivering 4096 × 2460 at 11.6 fps. The supported interface framework is GigE Vision V2.0, GenICam.