3D laser profile sensor · DP2000 series Laser Profiler

Hikrobot MV-DP2900

GigEIP673200 points per profile16.86…180.24 µm910 mm
Price on requestAn engineer will confirm pricing and lead time in the first reply.
Lead time
from 5 days
Warranty
36 months
Find the right model
Hikrobot MV-DP2900

Metre-class profile coverage

A 910 mm Z range at a 925 mm working distance places MV-DP2900 in the largest-envelope class of the DP2000 group. Its X field grows from 250 mm near through 485 mm at reference to 720 mm far. The 3200-point profile has 16.86 to 180.24 µm Z resolution, 6.59 µm repeatability and a high-frame-rate range of 1.7 to 23.9 kHz.

The long standoff and broad field support overall height, shape and edge measurement on large moving objects. The changing X coverage through Z must be included in the mechanical layout, particularly near the 250 mm end of the field. A Gigabit Ethernet link transfers profiles, while a 12-pin M12 connection provides 24 VDC power and isolated plus differential timing I/O.

MV-DP2900 extends beyond MV-DP2470's 670 mm Z range and 565 mm distance, trading its 4.45 µm repeatability for a 6.59 µm value over the larger volume. MV-DP3900 has a similar 905 mm range and 720 mm far field but reaches 46.7 kHz at a 947.5 mm working distance. Pick MV-DP2900 for DP2000-rate integration; move to MV-DP3900 when the higher scan ceiling governs.

Overview

A DP2000 series laser profiler — the base class: the sensor projects a laser line across the part and measures height at every point of the section, up to 3200 points per profile.

Working distance 925 mm, measurement range 910 mm.

Used where a profile is needed rather than a picture: weld bead control, adhesive bead height, gap and flush, warpage, parcel volume. Data goes to VM3D or 3DMVS, and to third-party software over a standard protocol.

Specifications

Data interfaceGigE (Fast Ethernet compatible)
3D scan rate1700…23900 Hz @ high frame rate mode
Depth measurement range910 mm
Points per profile3200
Reference distance925 mm
Reference field of view485 mm
Z repeatability6.59 µm
Z resolution16.86…180.24 µm
Trigger modesoftware, hardware; encoder @ differential, external trigger
Laser safety class3R
Wavelength650 nm
Client software3DMVS, VM3D, third-party software
Operating systemsWindows 7 (32/64-bit), Windows 10 (32/64-bit), Windows 11 (64-bit)
Digital I/O lines2 inputs, opto-isolated, lines 0, 9; 2 inputs, differential, lines 3, 6; 1 output, differential, line 1
Digital output count1
Digital I/O connectorM12 12-pin
Power supply24 V
Power deliveryexternal power supply
Power consumption15.2 W (typical) @ DC, supply voltage 24 V
Ingress protectionIP67
Working temperature0…45 °C
Storage temperature-30…80 °C
Humidity20…85 %
Dimensions275.6×118.5×57 mm
Weight1780 g (approx.)
Far field of view720 mm
Near field of view250 mm
Operating environmentnon-condensing
Output data typeprofile, depth image, brightness image
Profile data interval76.5…250.1 µm
Z linearity-0.01…0.01 % @ % of measurement range
Recommended system CPUIntel Core i5
System memory required≥8 GB

Documents

Datasheet MV-DP2900-03P · PDF · 0.6 MB · English · revised 18 Dec 2025
Drawing MV-DP2900-03P · ZIP · 46.3 MB

Selection and applications

Metre-class height measurement through a 910 mm Z range. Large-object contour capture across a 485 mm reference field. 3200-point moving-line profiling up to 23.9 kHz.

Minimum kit: MV-DP2900, a Gigabit Ethernet cable, a 12-pin M12 power and I/O cable, a 24 VDC supply, and a 3DMVS, VM3D or third-party software host form the minimum acquisition kit.

Nearby in the range: MV-DP2470 — Prefer it for a 670 mm Z range at the shorter 565 mm working distance and 4.45 µm repeatability; MV-DP3900 — Prefer it when a comparable 905 mm Z range must be profiled at up to 46.7 kHz.

Cables and accessories for this model

Compatibility per manufacturer data.

All accessory families →

FAQ

What volume does MV-DP2900 cover at its near, reference and far planes?

The Z range is 910 mm at a 925 mm working distance. Across that depth, the X field expands from 250 mm near to 485 mm at reference and 720 mm far. Fixture and target clearance should be checked against all three widths.

What profile resolution is available over the MV-DP2900 field?

MV-DP2900 records 3200 points per profile. X resolution changes from 76.5 to 250.1 µm and Z resolution from 16.86 to 180.24 µm across the volume. The listed Z repeatability is 6.59 µm under the gauge-block test condition.

How quickly can MV-DP2900 acquire profiles from a moving object?

The high-frame-rate range is 1.7 to 23.9 kHz. The appropriate value depends on the longitudinal profile spacing required at the machine's motion rate, while each transverse profile retains its 3200 measurement points.

Which electrical interfaces connect MV-DP2900 to the line?

Profile transmission uses 1000 Mbit/s Gigabit Ethernet with compatibility for 100 Mbit/s Fast Ethernet. The 12-pin M12 power and I/O connector supplies 24 VDC and provides two isolated inputs, two differential inputs and one differential output.

What housing and temperature limits apply to the MV-DP2900?

The IP67 housing measures 275.6 × 118.5 × 57 mm and weighs approximately 1780 g. Operation is specified from 0 to 45 °C, storage from -30 to 80 °C, and humidity from 20 to 85% RH without condensation.

Which software routes are named for handling MV-DP2900 profiles?

The software choices are 3DMVS, VM3D and third-party software. The 3200-point profiles are carried over Gigabit Ethernet, so host processing and link capacity should be matched to the active rate within 1.7 to 23.9 kHz.

Typical applications