3D laser profile sensor · DP3000 series Laser Profiler

Hikrobot MV-DP3580

GigEIP673200 points per profile14.45…98.78 µm580 mm
Price on requestAn engineer will confirm pricing and lead time in the first reply.
Lead time
from 5 days
Warranty
36 months
Find the right model
Hikrobot MV-DP3580

Fast large-volume contour acquisition

A 580 mm Z range and 585 mm working distance give MV-DP3580 a large measurement volume, while a 3.4 to 46.7 kHz high-frame-rate range supports fast motion. The X field spans 174 mm near, 328 mm at reference and 482 mm far. Profiles contain 3200 points, with 14.45 to 98.78 µm Z resolution and 4.84 µm repeatability.

The combination supports overall height, shape and edge tracking on large moving objects without placing the sensor close to the surface. Profile, depth and brightness outputs are available over Gigabit Ethernet. Software or differential-encoder hardware triggering aligns scans with motion, and a 12-pin M12 connection carries 24 VDC plus isolated and differential I/O.

MV-DP3580 raises the rate ceiling over MV-DP2470, which covers 670 mm along Z but reaches 23.9 kHz and states 4.45 µm repeatability. MV-DP3900 keeps the 46.7 kHz ceiling while expanding the Z range to 905 mm and the reference field to 495 mm, with 8.12 µm repeatability. Select MV-DP3580 when 580 mm of depth and finer repeatability are sufficient; move to MV-DP3900 for the larger volume.

Overview

A DP3000 series laser profiler — the mid class: the same 3200 points per profile at twice the scan rate, up to 46.7 kHz.

Working distance 585 mm, measurement range 580 mm.

Used where a profile is needed rather than a picture: weld bead control, adhesive bead height, gap and flush, warpage, parcel volume. Data goes to VM3D or 3DMVS, and to third-party software over a standard protocol.

Available versions

One device, different revisions. We ship the current one by default; if a specific revision is already installed on your line, name it in the request and we will match it.

Part numberPN
MV-DP3580-01P306400451
MV-DP3580-03P306400453

Specifications

Data interfaceGigE (Fast Ethernet compatible)
3D scan rate3400…46700 Hz @ high frame rate mode
Depth measurement range580 mm
Points per profile3200
Reference distance585 mm
Reference field of view328 mm
Z repeatability4.84 µm
Z resolution14.45…98.78 µm
Trigger modesoftware, hardware, encoder
Client software3DMVS, VM3D
Operating systemsWindows 7 (32/64-bit), Windows 10 (32/64-bit), Windows 11 (64-bit)
Digital I/O lines2 inputs, opto-isolated, lines 0, 9; 2 inputs, differential, lines 3, 6; 1 output, differential, line 1
Digital output count11
Digital I/O connectorM12 12-pin
Power supply24 V
Power consumption17.2 W (typical) @ DC, supply voltage 24 V
Ingress protectionIP67
Working temperature0…45 °C
Storage temperature-30…80 °C
Dimensions210.5×125.5×59 mm
Weight1550 g (approx.)
Far field of view482 mm
Near field of view174 mm
Operating environmentnon-condensing1
Output data typeprofile, depth image, brightness image
Profile data interval50.3…159.4 µm
Z linearity-0.01…0.01 % @ % of measurement range
Power supply connectorM12 12-pin
Recommended system CPUIntel Core i5
Trigger signallingdifferential @ differential, encoder trigger
Part numberLaser safety classWavelengthHumiditySystem memory required
MV-DP3580-01P
3B
405 nm
20…85 % @ non-condensing
≥8 GB
MV-DP3580-03P
3R
650 nm
20…85 %
≥8 GB (min.)

1 not stated for all variants

Documents

Datasheet MV-DP3580-01P · PDF · 0.5 MB · English · revised 18 Dec 2025
Datasheet MV-DP3580-03P · PDF · 0.5 MB · English · revised 18 Dec 2025
Drawing MV-DP3580-01P · ZIP · 27.7 MB
Drawing MV-DP3580-03P · ZIP · 27.8 MB

Selection and applications

Large-object height measurement through a 580 mm Z range. Broad contour capture across a 328 mm reference field. Encoder-triggered 3200-point profiling up to 46.7 kHz.

Minimum kit: MV-DP3580, a Gigabit Ethernet cable, a 12-pin M12 power and I/O cable, a 24 VDC supply, and a 3DMVS, VM3D or third-party software host form the minimum acquisition kit.

Nearby in the range: MV-DP2470 — Prefer it for a 670 mm Z range and 4.45 µm repeatability when 23.9 kHz is sufficient; MV-DP3900 — Prefer it for a 905 mm Z range and 495 mm reference field at rates up to 46.7 kHz.

Cables and accessories for this model

Compatibility per manufacturer data.

All accessory families →

FAQ

What measurement volume surrounds the MV-DP3580 reference distance?

The sensor covers 580 mm along Z at a 585 mm reference distance. X width changes from 174 mm near through 328 mm at reference to 482 mm far, so the target and fixture clearances must be checked throughout the full expanding volume.

What profile detail is available across the MV-DP3580 field?

Each profile contains 3200 points. The X interval ranges from 50.3 to 159.4 µm, and Z resolution ranges from 14.45 to 98.78 µm. The stated Z repeatability is 4.84 µm under the cited gauge-block measurement condition.

Which scan-rate limits are listed for the MV-DP3580 executions?

The main high-frame-rate entry runs from 3.4 to 46.7 kHz. A separate entry states a 19 kHz maximum in ROI mode. The model has 01P and 03P documents, so the selected execution determines which rate entry governs.

How can MV-DP3580 acquisition be synchronized to a moving axis?

The listed trigger methods are software trigger and hardware trigger from a differential encoder. A 12-pin M12 interface provides isolated and differential timing channels, while the 3200-point profile stream travels over Gigabit Ethernet.

What power and environmental limits apply to MV-DP3580?

Typical consumption is 17.2 W from a 24 VDC supply. The IP67 housing operates from 0 to 45 °C and stores from -30 to 80 °C. Humidity is specified from 20 to 85% RH without condensation.

Which applications can receive output from the MV-DP3580?

3DMVS, VM3D and third-party software are listed. The available measurement products are profile data, depth images and brightness images, transferred over 1000 Mbit/s Gigabit Ethernet with 100 Mbit/s Fast Ethernet compatibility.

Typical applications