Area camera · CT series

Hikrobot MV-CT0MG0016/G

1440 × 1080 pxStacked BSI78.2 fps @ 1440 × 1080 Mono 8Gigabit EthernetIP40
Price on requestAn engineer will confirm pricing and lead time in the first reply.
Warranty
36 months
Find the right model
Hikrobot MV-CT0MG0016/G

BASE version: what you get

This camera comes in three versions on the same sensor — they differ in protection, connectors and integrated optics:

Same sensor, other versions:

Same version, other sensor variant:

Engineering fit in the CT range

Moderate-resolution mono capture at 78.2 fps gives this model a speed-led position. MV-CT0MG0016/G places 1440 × 1080 px of monochrome data behind a global-shutter Stacked BSI CMOS sensor. It reaches 78.2 fps, uses 3.45 × 3.45 µm pixels across a 1/2.9-inch format, and sends frames over Gigabit Ethernet via the RJ45 connector.

The global shutter and 78.2 fps ceiling support grayscale feature location, orientation checks and mark-presence inspection, with the full field exposed on the same timing basis. Exposure extends through 23 µs to 10 s. Trigger Width and Trigger Controlled modes allow exposure to follow external timing. The 29 mm × 29 mm × 42 mm (1.1" × 1.1" × 1.7") body accepts C-mount optics. IP40 protection applies with proper lens installation and wiring, and the working range is –30 °C to 60 °C (–22 °F to 140 °F).

Neighbouring cameras show where this combination should be retained. MV-CT0CG0016/G keeps 1440 × 1080 px and 78.2 fps but changes the output to Color. MV-CT0CU0016/G uses USB 3.0 for 1440 × 1080 px colour capture at 249 fps. MV-CT0MG0020/G provides 1624 × 1240 px at 60.3 fps with a global-shutter monochrome path over Gigabit Ethernet. Retain MV-CT0MG0016/G when Mono output, Gigabit Ethernet and PoE are needed together at 78.2 fps.

Specifications

Order codeMV-CT0MG0016/G/NN/NN
Product type1.6 MP GigE Area Scan Camera
Sensor typeCMOS, global shutter
Sensor modelStacked BSI
Sensor format1/2.9″
Resolution1440 × 1080 px
Pixel size3.45 × 3.45 μm
Maximum frame rate78.2 fps @ 1440 × 1080 Mono 8
Mono colorMono
Pixel formatMono 8/10/10Packed/12/12Packed
BinningSupports 1 × 1, 2 × 2, 4 × 4
DecimationSupports 1 × 1, 2 × 2, 4 × 4
Reverse imageSupports horizontal and vertical reverse image output
Dynamic range68.5 dB
Exposure time23 μs to 10 sec
Exposure modeOff/Once/Continuous exposure mode, supports Trigger Width and Trigger Controlled
Gain0 dB to 24 dB
SNR44 dB
Data interfaceGigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s)
Digital I/O8-pin M8 A-Code aviation connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto-isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2).
Lens mountC-mount
Operating system32/64-bit Windows 7/10, 64-bit Windows 11, 32/64-bit Linux
Power supply9 VDC to 24 VDC, supports PoE
Power consumption typTyp. 1.4 W @ 12 VDC
Ingress protectionIP40 (under proper lens installation and wiring)
Operating temperature–30 °C to 60 °C (–22 °F to 140 °F)
Storage temperature–30 °C to 80 °C (–22 °F to 176 °F)
Humidity20% RH to 95% RH (no condensation)
Dimensions29 mm × 29 mm × 42 mm (1.1″ × 1.1″ × 1.7″)
WeightApprox. 116 g (0.3 lb.)
CertificationCE, RoHS, KC
CompatibilityGigE Vision V2.0, GenICam
Data interface connectorRJ45 connector
Control interfaceNot supported
Client softwareMVS or third-party software meeting with GigE Vision Protocol

Selection and applications

Grayscale feature capture at 1440 × 1080 px. Triggered monochrome inspection with a global shutter. Full-frame acquisition up to 78.2 fps.

Minimum kit: Use MV-CT0MG0016/G with a C-mount lens, a Gigabit Ethernet cable to the RJ45 connector, and either PoE or 9 V DC to 24 V DC power through the 8-pin M8 A-Code connection.

Nearby in the range: MV-CT0CG0016/G — Prefer it for Color output at the same 1440 × 1080 px and 78.2 fps.; MV-CT0CU0016/G — Prefer it for Color output over USB 3.0 at 1440 × 1080 px and 249 fps.; MV-CT0MG0020/G — Prefer it for 1624 × 1240 px, 60.3 fps and global-shutter monochrome capture..

Compatible lens options

Cables and accessories for this model

Compatibility per manufacturer data.

Data cables
GigE
I/O & power cables
CT: power and I/O
Power
Power

All accessory families →

FAQ

Which suggested lenses cover the sensor in MV-CT0MG0016/G?

For MV-CT0MG0016/G, the C-mount matches are MVL-KF1628M-12MP and MVL-KF5024M-25MP. Their image circles cover the 1/2.9-inch sensor, and the 12 MP and 25 MP lens classes are above the camera’s 1440 × 1080 px matrix. Both therefore match the stated mount, sensor coverage and resolution requirement.

How should power and cabling be arranged for MV-CT0MG0016/G?

The camera accepts 9 V DC to 24 V DC and also supports PoE. The RJ45 connector carries Gigabit Ethernet; the 8-pin M8 A-Code connection provides DC power and I/O when separate power is used. Consumption is typically 1.4 W at 12 V DC.

What data interface and peak acquisition rate does MV-CT0MG0016/G provide?

Data uses Gigabit Ethernet at 1 Gbit/s through RJ45 and remains compatible with Fast Ethernet. The stated full-frame ceiling is 78.2 fps at 1440 × 1080 Mono 8. MVS and software meeting the GigE Vision protocol are supported.

How do shutter timing and exposure affect motion work with MV-CT0MG0016/G?

The CMOS sensor uses a global shutter, so all pixels share the exposure timing for moving-part capture. Full-frame rate is 78.2 fps, and the exposure range is 23 µs to 10 s. Trigger Width and Trigger Controlled operation are available.

Which image-reduction and I/O functions are available on MV-CT0MG0016/G?

Binning and decimation each support 1 × 1, 2 × 2 and 4 × 4 operation. Horizontal and vertical reverse-image output is available. The 8-pin M8 A-Code I/O provides one opto-isolated input, one opto-isolated output and one bidirectional non-isolated line for sequencing.

What enclosure conditions and temperature range apply to MV-CT0MG0016/G?

Operation is rated from –30 °C to 60 °C (–22 °F to 140 °F), with 20% RH to 95% RH (no condensation). The housing is 29 mm × 29 mm × 42 mm (1.1" × 1.1" × 1.7") and weighs approximately 116 g (0.3 lb.). Its IP40 rating applies under proper lens installation and wiring, so the station must provide conditions consistent with that protection level.

Typical applications